22.6 - TABLE OF PROGRAMMING PARAMETERS
PARAMETER VALUE SUBMENU DESCRIPTION DEFAULT CHAPTER MEMO
MODE
Working mode
STAN
18
STAN
Standard
PRES
Deadman
S.PRE
Mixed
OROL
Timer
DIR
Gate direction (the direction you see from
the inside)
DX
DX
Thegateopensrightwards
SX
Thegateopensleftwards
P.APP 0-100%
Partial opening
50%
T.PRE 0.5”-10.0”
Pre-blinking time before opening
1.0”
13
NO
Functiondisabled
T.PCH 0.5”-10.0”
Pre-blinking time before closing
NO
13
NO
Pre-ashingduringclosingequaltoT.PRE
POT 30-100%
Motor power
100
9
VEL 5-99HZ
Normal speed
50
9
VEL.R 5-99HZ
Slowed speed
25
9
SPUN 0-30%
Over voltage at start opening
0
9
ACCEL 0-6
Starting ramp
2
9
DECEL 0-6
Slowing ramp
2
9
FRENO 0-10
Brake intensity
4
9
RAL.A 0-50%
Slowed opening run
10%
9
RAL.C 0-50%
Slowed closing run
10%
9
VEL.M 5-99HZ
Speed in manual operation
30
19
ST.AP
Start during the opening phase
PAUS
16
PAUS
Thegatestopsandpauses
CHIU
Thegateimmediatelystartsclosing
NO
Thegatecontinuestoopen(thecommandis
ignored)
ST.CH
Start during the closing phase
STOP
16
STOP
Thegatestopsandthecycleisconsideredas
complete
APRE
Thegatere-opens
ST.PA
Start during pause
CHIU
16
CHIU
Thegatestartsclosing
NO
Thiscommandisignored
PAUS
Thepausetimeisreset