AUTOMATIC CLOSING
Permits the selection between
the semiautomatic or automatic
functioning. By the
semiautomatic
functioning the command of
START or PEDESTRIAN START
opens the gate, when the
opening is complete the gate
remains still until the successive
command of opening, which will
reclose it. On the other hand, it
stops automatically and remains
in pause phase for the set time
(
t.PAU), then it closes again
through the set closing time.
no the automatic reclosing is not available, the gate is semiautomatic.
t.PAU the reclosing is available, the standstill time is set from 0 to 999.
If the function is
t.PAU, the display shows 10.0: set the wished time pressing the UP or DOWN keys.
mIMPORTANT: If the automatic reclosing is not available, is necessary to enable the start
command in pause(menu St.PA)