6 - ELECTRICAL CONNECTIONS
EL
1 2 3 4 5 6 7 8
C
M
VH
VRE F
VL
PH 01
PH 02
GND
+ VA
GS I
OL 1
CL 1
OL 2
CL 2
ST R
GND
GND
ST P
PED
ANT
GND
AUX
C
M
N L
HAZ
TRANSF
PRI M
START
RADIO
SET
ERROR
STOP
PHOTO
START
RADIO
SET
L Power phase 230 VAC
N Neutral 230 VAC
HAZ Flashing light 230Vac max 15W
AUX AUX contact / electric lock
PH 01 Photocell / safety edge.
Normally closed contact
PH 02 Photocell / safety edge.
Normally closed contact
GND Common of the PH01 - PH02 terminals
+VA Rated power 24Vdc
GSI Positive gate PILOT LIGHT (24Vdc, max3W)
OL 1 Opening limit switch
CL 1 Closing limit switch
ST R START: normally open contact
GND Common of the STR - STP - PED terminals
ST P STOP: normally closed contact
PED PEDESTRIAN START: normally open contact
ANT Antenna shield
GND Antenna