Installation vacon • 69
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
5
The sheet metal airflow guides (deflectors) marked in green prevents air circulation between
different sections of the equipment. The shield guides marked in green prevent air circulation inside
a section. The points marked in red show the exhaust air holes. These holes must not be covered,
nor must anything be placed above them to stop the free exit of warm air from inside the equipment.
The points marked in blue show the cooling air intake holes. These holes must not be blocked in any
way.
The materials used for preventing the circulation of air inside the equipment must be fire-
restraining. The edges must be sealed to prevent the formation of gaps. When the deflectors are
made according to the instructions, no separate cooling fan is required.