Brake Chopper Application – Parameter lists vacon 9
24-hour support +358 (0)40 8371 150 • Email: vacon@vacon.com
3.4 Output signals (Control keypad: Menu G2 Æ G2.3)
3.4.1 Digital outputs (G2.3.1)
Code Parameter Default Min Max Unit ID Note
P2.3.1.1 DO1 Ctrl 1 0 6 1216 Signal Selection for DO1
P2.3.1.2 DO2 Ctrl 2 0 6 1217 Signal selection for DO2 (RO1)
P2.3.1.3 DO3 Ctrl 3 0 6 1218 Signal selection for DO3 (RO2)
P2.3.1.4 DO4 Ctrl 0 0 6 1385 Signal Selection for DO4
P2.3.1.5 DO5 Ctrl 0 0 6 1386 Signal selection for DO5
P2.3.1.6 DO6 Ctrl 0 0 6 1390 Signal selection for DO6
P2.3.1.7 DO7 Ctrl 0 0 6 1391 Signal Selection for DO7
P2.3.1.8 DO8 Ctrl 0 0 6 1395 Signal selection for DO8
P2.3.1.9 DO9 Ctrl 0 0 6 1396 Signal selection for DO9
P2.3.1.10 DO10 Ctrl 0 0 6 1423 Signal Selection for DO10
P2.3.1.11 DO11 Ctrl 0 0 6 1427 Signal selection for DO11
P2.3.1.12 DO12 Ctrl 0 0 6 1428 Signal selection for DO12
P2.3.1.13 DO13 Ctrl 0 0 6 1429 Signal selection for DO13
Table 3-5. Digital output parameters G2.3.1
3.4.2 Analog output 1 (G2.3.2)
Code Parameter Default Min Max Unit ID Note
P2.3.2.1 AO1 Signal ID 0 0 2000 1233
Set the ID no. of a signal to be
connected to AO1
P2.3.2.2 AO1 Offset 0 0 1 1234
Minimum voltage or current
at AO1. 0= 0V/0mA, 1= 4mA
P2.3.2.3 AO1 Filter 10 0,02 10,00 s 1235
Filter time for the signal
selected for AO1 in Seconds.
P2.3.2.4 AO1 Max. Value 1500 -30000 30000 1236
Maximum value of a signal
selected for AO1. This will
correspond to +10V/20mA.
P2.3.2.5 AO1 Min. Value 0 -30000 30000 1237
Minimum value of a signal
connected to AO1. This will
correspond to 0V/0mA or
2V/4mA depending on the
type of AO1.
Table 3-6. Analog output parameters G2.3.2
3.5 BCU In parallel (Control keypad: Menu G2 Æ G2.4)
Code Parameter Default Min Max Unit ID Note
P2.4.1 Drooping 0 0,00 100,00 % 620
Increase in braking current
will increase the DC link
voltage level for operation as
a function of drooping.
Table 3-7. BCU In Parallel parameters G2.4