Alarm list
221. WorkStation 1 not connected
If Gateway loses contact with
WorkStation 1 during operation:
Check the cabling between Gateway and WorkStation.
Check that the cable is not trapped or otherwise damaged.
Check the condition of the connectors.
If the machine has a WS2 —check the connector on WS2
231. WorkStation 2 not connected
If Gateway loses contact with
WorkStation 1 during operation:
See alarm no 221
250. Seed level sensor Check the sensors cable, contacts and connections.
260. Grass seed level sensor
(BioDrill)
Check the sensors cable, contacts and connections.
270. Interruption to communication For some unknown reason Gateway has lost communication with the terminal,
e.g. if the terminal has been switched off or the iPad has been out of Wi-Fi
range. Acknowledge the alarm in the alarms menu. Feed stops.
If the fault recurs. Check the cabling for supply voltage to the terminal and the cabling between
Gateway and the terminal.
If the iPad is not communicating with the dock, check whether Bluetooth is
enabled.
281. Rotation guard, fertiliser LH
If the metering units do not move: Check connections and connectors to the tramline coupling.
If the alarm appears despite the
metering units rotating:
Check the sensor. The sensor is located in the tramline coupling, could be
defective.
Check that the roller in the coupling is rotating with the feed shaft. The roller
should rotate when tramlining is off.
282. Rotation guard, fertiliser RH See alarm no 281
283. Rotation guard, fertiliser LH
and RH
See alarm no 281
290. Hydraulic motor, fertiliser See alarm no. 40
300. Low level, fertiliser Check the fertiliser level in the hopper.
If there is fertiliser in the hopper: The sensitivity of the sensor has been incorrectly set.
310. Fertiliser valve, max power Perform a new calibration
Check the oil flow rate
320. Hopper level alarm, fertiliser Check the sensors cable, contacts and connections.
451. Fertiliser tramlining LH Check the sensors cable, contacts and connections.
Check the sensor.
452. Fertiliser tramlining RH See alarm no. 451