Please be aware that the efficiency of the generators themselves is decreasing the overall
SFOC value by a certain percentage.
Analog input
Signal
Type of input
signal
Terminal number on SPU3
Backplane-‘X’
Shaft generator one
420mA - active
Terminal nr. X1 and X2
Shaft generators two
420mA - active
Terminal nr. X1 and X2 + X3 and X4
Shaft generator one
420mA - passive
Terminal nr. X5 and X6
The number of Backplane-“X” might differ per PEM4 configuration, depending on the total
system. Please refer to the connection diagram what comes with the project.
Modbus input
Signal
Type of input
signal
Terminal number on SPU3
Shaft generator one
Modbus
Terminal nr. J1 (see section 6.12)
Shaft generators two
Modbus
Terminal nr. J2 (see section 6.12)