Appendix
34 Installation and maintenance instructions ecoFIT pure 0020230533_01
Fault code Meaning Possible cause
F.84 Fault: Flow/return temperature sensor Values not consistent, difference < -6 K
Flow and return temperature sensors signalling implausible values: Flow and
return temperature sensors have been inverted, flow and return temperature
sensors have not been correctly installed
F.85 Fault: Temperature sensor The flow and/or return temperature sensors have been installed on the same
pipe/incorrect pipe
Temperature sensor not connected or is connected incorrectly
F.86 Fault: Underfloor heating contact Underfloor heating contact open, sensor disconnected or defective
F.87 Fault: Electrodes Electrodes not connected or they are connected incorrectly, short circuit in
the cable harness
F.88 Fault: Gas valve Gas valve not connected or it is connected incorrectly, short circuit in the
cable harness
F.89 Fault: Pump Pump not connected or it is connected incorrectly, incorrect pump connec-
ted, short circuit in the cable harness
Connection No communication between the PCB
and the user interface
Electronics defective

Table of Contents

Other manuals for Vaillant ecoFIT pure

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant ecoFIT pure and is the answer not in the manual?

Vaillant ecoFIT pure Specifications

General IconGeneral
Fuel TypeNatural Gas
Dimensions (H x W x D)700 x 390 x 295 mm
ErP RatingA
MountingWall-mounted
Modulation1:5
TypeCombination Boiler
Warranty2 Years
Efficiency Rating94%

Related product manuals