EasyManua.ls Logo

Vaillant ecoTEC plus VUW 6/5-5 Series - Operation; 8.2 Installer Level Access; 8.3 Live Monitor (Status Codes); 8.4 Setting Hot Water Temperature

Vaillant ecoTEC plus VUW 6/5-5 Series
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
0020244997_07 Installation and maintenance instructions 31
8 Operation
8.1 Operating concept
The operating concept and the read-off and setting facilities
of the operator level are described in the operating instruc-
tions.
An overview of the reading and setting options for the in-
staller level is included in the table in the appendix.
Installer level Overview ( Page 52)
8.2 Calling up the installer level
1. Only call up the installer level if you are a competent
person.
2. Navigate to Menu Installer level and confirm by
pressing .
3. Set the value 17 (code) and confirm by pressing .
8.3 Live Monitor (status codes)
Menu Live monitor
Status codes in the display provide information on the pro-
duct's current operating mode.
Status codes Overview ( Page 59)
8.4 Setting the hot water temperature
Validity: Product with integrated hot water generation OR Product with hot
water generation through external domestic hot water cylinder
Danger!
Risk of death from legionella.
Legionella multiply at temperatures below
60 °C.
Ensure that the end user is familiar with
all of the Anti-legionella measures in order
to comply with the applicable regulations
regarding legionella prevention.
Set the hot water temperature.
Condition: Water hardness: > 3.57 mol/m³
Water temperature: 50

Table of Contents

Related product manuals