Operating instructions
For the operator
GB, IE
Operating instructions
ecoTEC plus
Gas-fired wall hung high efficiency boiler

Table of Contents

Other manuals for Vaillant ecoTEC plus

Questions and Answers

  • G
    George ClarkAug 29, 2025
    What does it mean if my Vaillant ecoTEC plus reports Electronics/NTC fault?
    • R
      robin62Aug 29, 2025
      An Electronics/NTC fault in your Vaillant Boiler indicates a short-circuit in the flow or return NTC, or defective electronics. Check and replace electronics or NTC.
  • J
    joseph90Aug 30, 2025
    What to do if my Vaillant ecoTEC plus Boiler electronics temperature is too high?
    • T
      Thomas WarrenAug 30, 2025
      If the electronics temperature is too high in your Vaillant Boiler, it could be due to the electronics being too hot from an external effect, or the electronics being defective. Ensure proper ventilation for electronics.
  • S
    schultzcameronAug 30, 2025
    What does it mean if my Vaillant ecoTEC plus Flow NTC reports a constant value?
    • M
      Mr. Samuel MacdonaldAug 30, 2025
      If the Flow NTC in your Vaillant Boiler reports a constant value, it means the Flow NTC is defective. Replace the Flow NTC.
  • N
    Nicole TapiaAug 25, 2025
    Why is my Vaillant ecoTEC plus Boiler not starting up, and there's no hot water or heating?
    • K
      Kerry HebertAug 25, 2025
      If your Vaillant Boiler isn't starting, resulting in no hot water and cold heating, several factors could be at play. First, ensure that both the on-site gas isolator cock and the product's gas isolator cock are open. Next, check if there's a power supply issue in your building by inspecting the fuse. If the boiler is switched off, turn it on. Also, verify that the heating flow and hot water temperatures are appropriately set. If these steps don't resolve the issue, there might be air in the heating installation, which requires purging by a professional. Finally, if the boiler enters fault mode (F.28) after three failed ignition attempts, press the fault clearance key. If the ignition fault persists after three clearance attempts, seek professional assistance.
  • A
    Angela SchwartzSep 1, 2025
    What to do if my Vaillant Boiler has a Flow–NTC open circuit?
    • F
      fletcheramandaSep 1, 2025
      If your Vaillant Boiler has a Flow–NTC open circuit, it could be due to a broken NTC, a broken NTC cable, a defective connection at the NTC, or a defective connection at the electronics. Check NTC and its connections.
  • J
    johnsonnicholasSep 1, 2025
    What to do if my Vaillant ecoTEC plus Boiler has a Return–NTC open circuit?
    • R
      Raymond TurnerSep 2, 2025
      If your Vaillant Boiler has a Return–NTC open circuit, it could be due to a broken NTC, a broken NTC cable, a defective connection at the NTC, or a defective connection at the electronics. Check NTC and its connections.
  • J
    Janice HamiltonSep 2, 2025
    What to do if my Vaillant Boiler has a Flow NTC short circuit?
    • S
      Stephen SchroederSep 2, 2025
      If your Vaillant Boiler has a Flow NTC short circuit, it could be due to a defective NTC, a short circuit in the cable harness, or a cable/casing short cut. Check for short circuit in cable harness or NTC.
  • J
    jamesrodriguezSep 3, 2025
    What to do if my Vaillant ecoTEC plus Boiler has a Return NTC short circuit?
    • B
      Blake JosephSep 3, 2025
      If your Vaillant Boiler has a Return NTC short circuit, it could be due to a defective NTC, a short circuit in the cable harness, or a cable/casing short cut. Check for short circuit in cable harness or NTC.
  • W
    William HillSep 3, 2025
    What to do if my Vaillant Boiler has a Tank NTC short circuit?
    • C
      Christopher MossSep 3, 2025
      If your Vaillant Boiler has a Tank NTC short circuit, it could be due to a defective NTC, a short circuit in the cable harness, or a cable/casing short cut. Check for short circuit in cable harness or NTC.
  • C
    Christine LeeSep 4, 2025
    What to do if Safety temperature limiter by NTC is activated on my Vaillant Boiler?
    • E
      Erica ZimmermanSep 4, 2025
      If the safety temperature limiter by NTC is activated on your Vaillant Boiler, it's because the Flow-NTC is not correctly thermal-connected or defective, and the appliance does not shut down. Check and correct thermal connection of Flow-NTC.

Summary

Safety

Safety and Warning Information

Explains the classification of warnings by severity (Danger, Warning, Caution) and the structure of warning messages.

Intended Use of the Boiler

Defines the proper and improper uses of the Vaillant ecoTEC plus boiler and the manufacturer's liability.

Basic Safety Instructions and Precautions

Covers installation, gas/flue gas safety, preventing scalding, material damage, and frost damage.

Description of Devices and Functions

Operation

Control Elements and System Overview

Introduces the control elements of the ecoTEC plus and the Digital Information and Analysis System (DIA).

Putting the Boiler into Service

Isolator Devices and Boiler Activation

Instructions for opening/closing isolator devices and switching the boiler on, with frost protection warnings.

Checking and Filling the Heating System

Guidance on checking the heating system's fill level and the procedure for filling it, including water quality advice.

Temporary Shutdown and Frost Protection

Guidance on temporarily shutting down the boiler and activating frost protection, including draining the system.

Energy Saving Tips

Troubleshooting

Reading Fault Messages

Explains how fault codes and plain text messages are displayed and what to do when they appear.

Malfunction Detection and Rectification

Provides a table for self-checking common problems like no hot water, heating failure, or low system pressure.

Ignition Faults and Maintenance Alerts

Addresses resolving ignition faults and recognizing maintenance messages, advising professional help when needed.

Additional Functions

Service and Maintenance

Boiler Servicing Recommendations

Emphasizes the importance of annual servicing by a qualified professional for optimal performance and longevity.

Manufacturers Guarantee and Service

Brief Operating Instructions

Vaillant ecoTEC plus Specifications

General IconGeneral
ModelecoTEC plus
CategoryBoiler
TypeCondensing
Dimensions (H x W x D)720mm x 440mm x 338mm
ErP RatingA
MountingWall-mounted
Output Range12kW to 38kW
Fuel TypeNatural Gas
Domestic Hot Water Output38kW
Flow Rate15.9 l/min
NOx EmissionsClass 5
Efficiency94% (SAP 2009)

Videos

How to repressurise your ecoTEC plus boiler

How to Operate Your Vaillant EcoTec PLUS Combination Boiler, Adjust Settings

How To Reset Vaillant Ecotec Plus Boiler

How to RESET the Vaillant ecoTEC Plus Boiler with a touch screen