EasyManuals Logo

Vaillant ecoTEC SERIES User Manual

Vaillant ecoTEC SERIES
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
Operating manual ecoTEC 0020052777_004
2 Safety
2.1 Erection and adjustment
Installation and adjustment of the boiler and service,
maintenance and repair work may only be carried out
by expert technicians in accordance with regulations in-
troduced in 1998 governing the safety of gas installa-
tions (installation and use). (In Great Britain "CORGI".
This means that the work carried out by registered in-
stallation companies must always be to a safe and satis-
factory standard.) If the boiler is mounted in a cabinet-
type enclosure the ventilation openings must not be ob-
structed and the enclosure must not be used for stor-
age purposes.
2.2 Action in case of emergency
d
Danger!
If you smell gas!
Risk of poisoning and explosion due to a
malfunction!
Procedure in case of gas smell in buildings
Open doors and windows wide, facilitate through
movement of air, stay out of rooms where gas odour
is present!
Avoid naked flames, do not smoke, do not use pocket
lighters!
Do not use electric switches, plugs, bells, telephones
and other communication systems in the building!
Close gas meter isolator device or main isolator de-
vice!
Close gas isolator cock (1, Fig. 2.1) on unit!
Warn other building residents, but avoid ringing door-
bells!
• Vacate building!
Inform the gas supply company stand-by service from
a telephone outside the building!
If a gas leak is audible, leave the building immediately,
prevent others from entering the building and notify
the police and fire brigade from outside the building!
1
Fig. 2.1 Closing the gas isolator cock
2.3 Safety instructions
Always observe the following safety instructions and
regulations.
d
Danger!
Inflammable mixtures of gas and air may ex-
plode!
Do not use or store explosives or highly flam-
mable substances, such as petrol or paint, in
the same room as the unit.
d
Danger!
Risk of poisoning and explosion due to a mal-
function!
Never put the safety devices out of operation
or tamper with them so as to impair their
function.
Therefore, do not attempt any modifications:
- to the unit,
- around the unit,
- to the gas, air, water and electricity supply pipes,
- to the expansion relief valve and drain line for the
heating water,
- to the flue gas pipes.
This also applies to alterations to structural elements in
the vicinity of the appliance which might affect its oper-
ational safety.
Example:
- If you require cabinet-type cladding for your unit, con-
sult your recognised expert technician company.
Under no circumstances must you enclose your device
arbitrarily. Enclosing the appliance in a cabinet re-
quires observance of special design instructions.
For alterations to the appliance or to its environment,
you must refer to the suitably qualified heating engi-
neer which is responsible for it.
2 Safety

Other manuals for Vaillant ecoTEC SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant ecoTEC SERIES and is the answer not in the manual?

Vaillant ecoTEC SERIES Specifications

General IconGeneral
ModelecoTEC SERIES
ErP RatingA
MountingWall-mounted
DimensionsVaries by model
WeightVaries by model
Fuel TypeNatural gas or LPG
NOx EmissionsClass 5 (less than 56 mg/kWh)
Output Range35kW

Related product manuals