9 Technical data
9.1 Technical data - VWS
Description Unit VWS 220/2 VWS 300/2 VWS 380/2 VWS 460/2
Type
Brine-to-water heat pump
Area of application
The heat pumps are intended exclusively for domestic use as heating appliances
for closed heating and hot water systems and for hot water generation.
Operation of the pump outside the application limits results in the heat pump
being switched off by the internal control and safety installations.
Fuse
- Trigger characteristics
- Breaking current
C, three-pole switching (disconnection of the three mains connection lines by a
switching operation)
A20253240
Electrical power consumption
- Min. for B-5/W35
- Max. for B20/W60
- External auxiliary heater (on-site,
max.)
kW
kW
kW
5,0
10,0
3 x 2,3
6,4
12,0
3 x 2,3
8,5
16,0
3 x 2,3
10,1
18,0
3 x 2,3
Coolant circuit
- Coolant type - R 407 C
Heat pump performance data The following performance data is applicable to new units with clean heat exchangers.
B0/W35 DT 5K In accordance with
DINEN 14511
- Heating output
- Power consumption
- Output figure/coefficient
of performance COP
B0/W35 DT 10K In accordance with
DINEN 255
- Heating output
- Power consumption
- Output figure/coefficient
of performance COP
B0/W55 DT 5K In accordance with
DINEN 14511
- Heating output
- Power consumption
- Output figure/coefficient
of performance COP
kW
kW
-
kW
kW
-
kW
kW
-
22,0
5,0
4,4
22,3
4,7
4,60
20,3
6,6
3,1
29,8
6,5
4,6
30,3
6,3
4,8
26,8
8,8
3,0
38,3
8,5
4,5
37,8
8,0
4,7
36,2
11,7
3,1
45,9
10,0
4,6
45,5
9,7
4,7
42,3
14,1
3,0
Interior noise level
(B0/W35 in accordance with EN 12102)
dB(A) 63 63 63 65
Installation site
- Permitted ambient temperature °C
Int
erior/dry
7 - 25
9.1 Technical data - VWS
Key
B0/W35 DT 5K:
B = Brine
0 = 0 °C Inlet temperature/warm brine
W = Heating water
35 = 35 °C Flow temperature
DT= Temperature difference based on flow and return of the
heating mode
K = Kelvin
9

Table of Contents

Other manuals for Vaillant geoTHERM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant geoTHERM and is the answer not in the manual?

Vaillant geoTHERM Specifications

General IconGeneral
BrandVaillant
ModelgeoTHERM
CategoryHeat Pump
LanguageEnglish

Related product manuals