30 VRT 360 Installation Manual
10 Electrical installation
10 Electrical installation
The electrical connection may only be
carried out by a suitably qualified engi-
neer.
Danger!
Risk of fatal electric shock from
touching live connections. Before
working on the room thermostat,
turn off the power supply and
secure against restart.
10.1 Connecting the room thermostat
Communication to the boiler takes place
using a 2-core bus cable (eBus). All eBus
connector plugs are designed to allow at
least 2 x 0.75 mm
2
(recommended) per
connection terminal. This means that the
wires can be swapped without impairing
communication (fig. 10.1). Also follow the
instructions for the boiler. Do not
remove the jumper between terminals 3
and 4 on the boiler.