Chapter 4 ___________________________________________________________ Troubleshooting
VAISALA______________________________________________________________________ 133
System Information
You can acquire a report that contains system information by using the
SYSINFO terminal command. The command lists parameters that are
useful especially when troubleshooting the system or when contacting
Vaisala HelpDesk.
Example:
/ > sysinfo
Serial # : E091041
Hardware : Rev B-003
Software : 7.00b
Checksum : 0ABACAB0
Boot sw version : 8.00
Program flash : 4096kB
System RAM : 2048kB
Free memory : 1297kB
Internal temp. : 25.50'C
Active errors : NO
Active warnings : NO
Piggyback - 0 : N/A
Piggyback - 1 : DSE101 rev: B serial no: 904460
Setup file : /Cfg/m120_425.adc
Setup for sw : 7.00
Setup creator : JI
Setup created : 2010-04-16T14:21:36+00:00
Setup CRC : EE848764
Lizard version : 7.00
System uptime : 168h 33min 51sec since Tue Apr 27
12:44:11 2010
where
Serial # = Serial number of the logger PCB
Hardware = Hardware revision of the logger PCB
Software = Software version for the operating software and
its checksum
Boot sw version = Version of the QML logger boot software
Program flash = Total amount of program memory
System RAM = Total amount of memory on the logger
Free memory = Amount of free memory on the logger
Internal temp. = Internal temperature of the logger