User's Guide ______________________________________________________________________
54 ___________________________________________________________________M210784EN-E
5. If you have multiple QML loggers on the same network and you
are going to access them over the same dial-up connection, you
need a unique identifier for each logger. To uniquely identify the
logger for which you are creating an Address Book entry, enter a
unique alphanumeric string in the Station id field. However, if you
only have a single logger on the network, you can leave the Station
id entry blank.
6. In the Command wait timeout (ms) field, enter a value in
milliseconds that specifies for how long AWS Client will wait for
the logger to respond when AWS Client sends a requests over the
dial-up connection. If the request, for instance, a log file download,
succeeds within the timeout, a success message is displayed. If the
request fails, a failure message is displayed instead, and you have
the option to try again at a later time. Factors such as the current
load on the logger, delays in the connection, and the response
length affect whether or not the timeout will expire during a
request. In case the system has a large amount of static parameters,
the set static parameters command can require a long command
wait timeout.
7. From the Dial-up modem entry pull-down menu, select an ISP
Name, that is, a Windows Dial-up Networking entry, that you
created as a prerequisite for this address book entry.
8. Save your settings and return to the Address Book window by
selecting Save.