VFlex Corner Sequencing
Control Panel
Owner's Manual
0999114_B
© 2018 Valmont Industries, Inc., Valley, NE 68064 USA. All rights reserved.
www.valleyirrigation.com

Table of Contents

Questions and Answers

  • V
    Virginia WilliamsAug 20, 2025
    What to do if the screen is dark on Valley Farm Equipment?
    • R
      Ronnie YoungAug 20, 2025
      If the screen is dark on your Valley Farm Equipment, it might be due to the contrast being set too high or too low. Try adjusting the contrast by pressing the home key to go to the status screen, and then use the up or down arrow keys to adjust it. If that doesn't work, contact your Valley dealer.
  • R
    Ryan RogersAug 22, 2025
    What does error E11 mean on Valley Farm Equipment?
    • C
      Christian FrostAug 22, 2025
      This error on Valley Farm Equipment indicates that the STB flash memory is corrupt. Please contact your Valley dealer for assistance.
  • R
    Richard NovakAug 25, 2025
    What does error E02 mean on Valley Farm Equipment and how to fix it?
    • J
      James NielsenAug 25, 2025
      Error E02 on your Valley Farm Equipment indicates a checksum error in the EEPROM section of memory. This can occur if power is lost while entering constants, potentially resulting in data loss. Try a hard reset of the module. If the problem persists, contact your Valley dealer.
  • C
    Cynthia PattersonAug 26, 2025
    What does error E01 mean on Valley Vflex Farm Equipment and how can I resolve it?
    • R
      Rachel DavisAug 27, 2025
      Error E01 on your Valley Farm Equipment can be caused by an incorrect checksum in the BBRAM section of memory or weak batteries in the Real-time Clock (BBRAM). If this error occurs, replace the Real-time Clock. For further assistance, contact your Valley Dealer.
  • C
    Catherine WatersAug 28, 2025
    What does error E12 mean on Valley Vflex?
    • A
      Adam BowenAug 28, 2025
      Error E12 on Valley Farm Equipment indicates that the EEPROM memory is corrupt, potentially due to loss of power while saving machine configuration parameters or runtime data. Contact your Valley dealer for assistance.
  • C
    Carla JohnsonAug 30, 2025
    What does STB FLASH FAULT mean on Valley Farm Equipment?
    • A
      Ashley DayAug 30, 2025
      If your Valley Farm Equipment displays 'STB FLASH FAULT', it means the memory area containing the currently running software is corrupt. Contact your Valley dealer for assistance.
  • T
    Timothy StoutSep 1, 2025
    Why does the screen cycle on and off on my Valley Vflex Farm Equipment?
    • W
      Wendy MedinaSep 1, 2025
      If the screen on your Valley Farm Equipment cycles on and off, it suggests erratic incoming power. Contact your Valley dealer for assistance.
  • V
    Valerie WrightSep 2, 2025
    What does error E04 mean on Valley Farm Equipment?
    • G
      Gabrielle HuntSep 2, 2025
      If your Valley Farm Equipment shows error E04, it indicates a keypad failure or a stuck key. Contact your Valley dealer for assistance.
  • R
    Ryan SmithSep 4, 2025
    What does STB EEPROM FAULT mean on Valley Farm Equipment and how to fix it?
    • B
      brandon37Sep 4, 2025
      If your Valley Farm Equipment displays 'STB EEPROM FAULT', it means the memory area containing runtime parameters and machine configuration is corrupt. A hard reset may fix this error. If the issue persists, contact your Valley dealer.
  • H
    hwhiteSep 6, 2025
    What to do if the Valley Vflex Farm Equipment shows STB SOFTWARE error?
    • J
      Jeff AdamsSep 6, 2025
      If you're experiencing 'STB SOFTWARE' issue with your Valley Farm Equipment, it means that the STB was restarted unexpectedly. Contact your Valley dealer for assistance.

Summary

Electrical Safety Statements

Installation Safety for European Union

Details installation requirements for differential circuit breakers in the EU.

Manual Scope and Usage

Explains the scope of the manual and the need to use it with other related manuals.

Ancillary Equipment Warranty Responsibility

Clarifies owner's responsibility for warranty registration of ancillary equipment.

Safety

Recognize Safety Information

Explains hazard symbols, DANGER, WARNING, CAUTION messages.

Safety Messages and Information

Details the meaning of hazard symbols, DANGER, WARNING, CAUTION, and NOTE.

Personal Protective Equipment

Covers PPE requirements for electrical hazards and safe handling of conductive materials.

Fall Protection

Addresses fall hazards and the use of appropriate fall protection equipment.

Minimum Working Clearance

Details minimum working clearance requirements around electrical panels and equipment.

Qualified Person

Defines a qualified person and their role in working on de-energized electrical equipment.

Overhead Power Line Safety

Warns about hazards and clearance requirements when working near overhead power lines.

Lockout;Tagout Procedures

Establishes minimum requirements for locking out energy isolating devices during maintenance.

Operate Safely

Provides essential tips for safe operation, including emergency stopping and component safety.

Operational Safety Warnings

Covers various warnings and cautions for safe operation, including electrical hazards and component safety.

Safety Decals

Explains the importance of safety decals and identifies their locations on the machine.

Overview

VCS Control Panel and Term Definitions

Describes VCS control panel components and defines key terms used in the manual.

Corner Identification Configurations

Details component configurations for standard (trailing) and inverted (leading) corners.

Main Status Screen Elements

Explains the main status screen display, including time, angles, speed, and solenoids.

Function Key Operations

Explains the usage of function keys for programming and viewing data.

Numeric Entry and Navigation Keys

Details the usage of numeric entry and navigation arrow keys for input and menu navigation.

Manual Conventions and Screen Behavior

Explains symbols, conventions, command prompts, and screen delay behavior.

Operation

Starting the Control Panel

Outlines the steps and conditions for powering on and starting the VCS control panel.

Programs Key Functions

Explains how to use the Programs key for irrigation, chemigation, and override settings.

Corner Angles Configuration

Details how to configure solenoid valve controls based on different corner angles.

Machine Angles Configuration

Details how to configure solenoid valve controls based on different machine angles.

Retracted Psi Settings

Explains the Retracted Psi menu for pressure regulator settings.

Diagnostics

Diagnostics Screen Overview

Provides an overview of diagnostic features for identifying and correcting VCS failures.

System Faults and Viewing

Lists machine shutdown faults, their descriptions, and how to view them.

Error Code Summary

Summarizes possible error codes, their descriptions, and potential causes.

Error Logs and Viewing

Explains how error logs record error details and how to view them.

System Review Log and Status Changes

Details the system review log for status changes and associated error codes.

A;D - Analog to Digital Voltages

Details the use of analog channels for monitoring voltage feedback.

Modules and GPS Information

Explains how to review module status and GPS location and heading.

Troubleshooting

Troubleshooting Precautions

Lists essential precautions for safe troubleshooting and maintenance of the machine.

System Faults Description

Lists and describes possible system faults, their causes, and corrective actions.

Error Codes Description

Details possible error codes, their descriptions, thresholds, and corrective actions.

Troubleshooting Common Problems

Provides a list of common problems with their causes and corrective actions.

Executing a Hard Reset

Details the effects and steps for performing a hard reset on the control panel.

Valley Vflex Specifications

General IconGeneral
BrandValley
ModelVflex
CategoryFarm Equipment
LanguageEnglish

Related product manuals