observe the machine’s operation for 10 seconds at the most; (the
appliance may continue to run without ice cream mixture 10
seconds at the most; extended operation of the appliance without
mixture is not allowed!);
press the STOP / RESET key;
turn off the SAFETY SWITCH and the MAIN SWITCH;
place a suitable container under the ejection opening and empty the
water out of the cylinder (if necessary the procedure must be repeated);
Open the batch feeder cover.
remove the batch feeder cover lid and the safety net from the cylinder
doors;
place the batch feeder cover lid and the safety net on solid surface and
remove batch feeder cover lid from safety net;
With both hands graps and then push – rotate chute (in counter-
clockwise direction) for remove it .