1 Overview
This guide describes the installation of the ACT365-ACU controller.
The ACT365-ACU Controller is a single door IP controller that requires an external 12V or 24V power
supply.
The ACT365-ACU2A Controller is a single door IP controller with a 12V DC 2A PSU.
The ACT365-ACUPoE Controller is a single door IP controller that is powered over Ethernet.
Sign up to ACT365 via www.act365.eu.
1.1 Technical specification
ACT365-ACU ACT365-ACU2A ACT365-ACUPoE
Voltage Range (Controller) 1124V DC 1124V DC 1124V DC
Current Consumption
(Controller)
350mA (Max) 350mA (Max) 350mA (Max)
Controller Dimensions
(H x W x D mm)
165 x 235 x 55 275 x 330 x 80 275 x 330 x 80
Controller Weight (kg) 0.4 2.2 2.2
Operating Temperature -10 to +50° C -10 to +40° C
75% RH non-condensing
-10 to +40° C
75% RH non-condensing
Operating Environment Surface
mounting
Internal use
only
Surface mounting
Internal use only
Surface mounting
Internal use only
Enclosure Material ABS 1.2mm steel grey powder
coated
1.2mm steel grey powder
coated
LED Status Indicators Yes Yes Yes
PSU Fault Output n/a Yes Yes
Lid Opening Tamper Detection
(Front)
Yes Yes Yes
Rear Tamper Detection No Yes Yes
1.1.1 Electrical specification
ACT365-ACU ACT365-ACU2A ACT365-ACUPoE
PoE 802.3bt input (PoE++) N/A N/A 13.8V at 3A output + 0.5A battery
charge
PoE 802.3at input (PoE+) N/A N/A 13.8V at 1A output + 0.5A battery
charge