To interlock additional doors, continue linking OP3 and AUX I for each new door.
2. On the ACT365 customer portal, select the site from the site picker.
3. Under Access Control > Doors, for each interlock door:
a. Click the door name on the Doors screen.
b. Select the Interlock check box on the Update Door screen.
c. Click Save.
When Interlock is enabled on a door, the door is locked when the AUX input is active.
When the door is open, OP3 is active and pulls Aux I low (0V) on all interlock doors.
3.4 Intruder panel wiring
To arm/disarm an intruder panel:
1. Wire the intruder alarm panel to the controller as shown:
A Intruder alarm panel
B Connect the AUX Relay output from the controller to arm input on alarm panel. The AUX
Relay can be set to pulse or toggle. Toggle by programming the AUX Relay time to
zero.
C Connect a signal from the alarm panel to indicate armed or disarmed status. If 0V is
connected to AUX Input, the panel is armed.
2. Wire the door from which the system will be armed/disarmed.
3. On the ACT365 customer portal, select the site from the site picker.
4. On the ACT365 customer portal, program the ACT365-ACU:
a. Click Access Control > Doors > <Door Name>.
b. Under Aux Relay, select the Arm Intruder Panel check box.
c. Under Operation, select the Intruder Panel check box.
d. Click Save.
5. On the ACT365 customer portal, grant arm/disarm rights to users:
a. Click Access Control > Cardholders > <Card Holder Name>.
b. Under Options, select the Arm/Disarm check box
c. Click Save.
6. To arm the system, a user with arm/disarm rights should press the tick key on the keypad then
present their card. Once the intruder panel is armed (as monitored by the AUX I PIN), the Door