Vanderbilt ACT365-ACU - 1.1.2 Relay load; 1.2 Ordering details

Vanderbilt ACT365-ACU
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ACT365-ACU ACT365-ACU2A ACT365-ACUPoE
PoE 802.3af input (PoE) N/A N/A 13.8V at 0.3A output + 0.5A battery
charge
Battery charging N/A Yes Yes
Standby Battery N/A 12V 7Ah Battery 12V 7Ah Battery
Battery Deep Discharge
Protection
N/A No Yes
Input: Voltage Rated N/A 100240V AC N/A
Input: Voltage Operating N/A 90264V AC N/A
Input: Frequency N/A 5060Hz N/A
Input: Max Current N/A 1.0A (@ 90V AC) N/A
Input: Mains input fuse N/A T2.0A N/A
Input: Max standby power N/A 0.5W (no load and no
battery connected)
N/A
Output: Voltage N/A 13.4–14.2V DC
(13.8V DC Nominal)
on mains power
10.0–12.3V DC on
battery standby
N/A
Output: Max load current N/A 2.0A N/A
Output: Ripple N/A 150mA pkpk max N/A
Output: Load output fuse N/A F2.0A N/A
Output: Overload N/A Electronic shutdown
until overload or short
circuit removed
(Under mains power
only)
N/A
1.1.2 Relay load
When used with inductive loads (Maglock/Strike locks) the following ratings apply.
ACT365-ACU ACT365-ACU2A ACT365-ACUPoE
Main relay 1.5A @ 30VDC /
1.5A @ 50VAC
1.5A @ 30VDC /
1.5A @ 50VAC
1.5A @ 30VDC /
1.5A @ 50VAC
Aux relay 400mA @ 30VDC 400mA @ 30VDC 400mA @ 30VDC
1.2 Ordering details
ACT365-ACU V54502-C130-A100 Single door cloud IP controller
ACT365-ACU / ACT365-ACU2A / ACT365-ACUPoE Installation Instructions Overview
© Vanderbilt 2019 5 A-100521-c
15.03.2019