9
MAINTENANCE & CLEANING
Clean the housing using only a soft cloth or cotton swab with water or medical alcohol. Do not use cleaning agents
or solvents. Do not let any liquid enter the housing area. Allow the tool to fully dry before use.
Avoid storing the sensor in extreme temperature conditions. Do not store below -4° F (-20° C,) or where the radiant
temperature may exceed 140° F (60° C). For maximum accuracy, allow the temperature of the meter to reach room
temperature (70° F) (21° C) before use.
Always purchase the correct size and grade of battery most suitable for the intended use.
Clean the battery contacts and also those of the device prior to battery installation.
Remove batteries if consumed or if product is to be left unused for a long time.
Store and carry the tool inside the supplied protective case.
SPECIFICATIONS
Operating Environment: Indoor/Outdoor, Dry Locations
Maximum Scanning Depth:
Ferrous Metals (Steel): 80 mm (±10 mm accuracy*)
Non-ferrous Metals (Copper): 60 mm (±10 mm accuracy*)
Copper Conductors (live): 50 mm (±10 mm accuracy*)
Wood: 20 mm (±10 mm accuracy*)
Auto-off Delay Time: 6 min.
Battery: 9V, Alkaline
Battery Operating Lifetime: 6 hrs. approx.
Working Temperature: 14° to 104° F (-10° to 40° C)
Storage Temperature: -4° to 140° F (-20° to 60° C)
* IMPORTANT: Variance in accuracy may be higher depending on the condition, material and thickness of the
surface and the shape and size of the scanned object.