Pocket Laser Range Finder

Questions and Answers

  • R
    Ronnie GordonAug 4, 2025
    Why won't my Vectronix PLRF10 Measuring Instruments turn on?
    • Z
      zlewisAug 4, 2025
      If your Vectronix Measuring Instruments aren't functioning, the batteries may be depleted. Try replacing them. Also, check the battery contacts for corrosion and clean them if necessary. Low temperatures can also reduce battery performance, so warm them up. Avoid storing batteries above +70°C, as extreme heat can shorten their life.
  • S
    Steven GrantAug 8, 2025
    What to do if my Vectronix PLRF10 Measuring Instruments displays 'LobA'?
    • R
      Robert BentonAug 8, 2025
      If your Vectronix Measuring Instruments displays 'LobA', it means the battery is almost used up. Replace the battery.
  • M
    mendozalouisAug 14, 2025
    Why does my Vectronix PLRF10 Measuring Instruments display '– – – –' after distance measurement?
    • A
      Ashlee SwansonAug 14, 2025
      The '– – – –' display after a distance measurement indicates that the distance is outside the specified range. Respect the specified measurement range. It can also mean that the object is too small or inaccurately targeted, or that you are experiencing bad weather conditions. Respect the factors affecting measurement range.
  • J
    Juan HansenAug 18, 2025
    What does 'ntOn' mean on my Vectronix PLRF10 Measuring Instruments?
    • N
      Nicole CaseAug 18, 2025
      The display of 'ntOn' after a measurement indicates that the device is being used in daylight conditions with 'ntOn' selected in the configuration menu. To resolve this, select 'ntOF' in the configuration menu.
  • M
    Mrs. Maria ThomasAug 25, 2025
    How to fix Vectronix PLRF10 Measuring Instruments measuring wrong objects?
    • T
      Tyler ClarkAug 25, 2025
      If your device is measuring objects in front or behind the intended object, it might be because '3dOF' is set in the configuration menu, which only displays the distance with the highest return signal. Select '3dOn' in the configuration menu.
  • V
    Vickie GonzalezAug 28, 2025
    How to make electronic reticle visible on Vectronix PLRF10?
    • R
      Regina CastroAug 29, 2025
      If the electronic reticle is not visible, it is possible that 'ErOF' is set in the configuration menu. To make it visible, select 'ErOn' in the configuration menu.

Summary

General Information

Safety Notices

Covers safety warnings, inappropriate use, and associated risks.

Care and cleaning

Lens cleaning

Instructions for cleaning the device's optical lenses.

Cleaning the casing

Guidelines for cleaning the exterior of the rangefinder.

Technical Data

Optics

Details specifications related to the device's optical components.

Rangefinder

Technical specifications for PLRF10 and PLRF15 models.

Miscellaneous

Provides data on power, temperature, weight, and dimensions.

Getting started

Changing the batteries

Step-by-step guide for battery replacement.

Diopter adjustment

Instructions on adjusting the diopter for clear image focus.

Reticle

Explanation of glass and electronic reticle types.

General Operations

Details on operating the device using its keys.

Distance Measurements

Factors affecting measurement range

Illustrates factors influencing measurement accuracy and range.

Slope distance

Explains the procedure for measuring slope distance.

Multiple object measurement

Describes obtaining distances for multiple objects in a single measurement.

Configuration

Making adjustments

Guide to navigating and changing instrument settings.

Measuring 3 distances

Details the "3dOn" function for multiple distance measurements.

Electronic reticle

Explains the "ErOn" function for the electronic aiming mark.

Night vision device

Describes the "ntOn" function for night vision compatibility.

Night vision operation - Mount

Steps for attaching a night vision device.

Night vision operation - Remove

Steps for removing the night vision device.

Settings

Measurement units

How to select and set measurement units (meters, yards, feet).

Distance gate

Instructions for setting a minimum distance limit.

Set Factory Settings - Reset to default

Procedure for resetting the device to its factory default settings.

Built-in-Test

Troubleshooting

Data transfer

Connecting the interface cable

Guide on connecting the device to a computer via an interface cable.

Equipment

Parts List

Lists standard delivery components and spare parts.

Accessories

Details optional accessories available for the device.

Customer service

Quality system

Information on Vectronix's quality management systems.

Vectronix PLRF10 Specifications

General IconGeneral
BrandVectronix
ModelPLRF10
CategoryMeasuring Instruments
LanguageEnglish