3 Product description
VEGAMET 141 • 4 … 20 mA
63728-EN-210129
3.2 Principle of operation
Controller VEGAMET 141 feeds the connected 4 … 20 mA sensor,
processes the measured values and displays them. The compact
design is ideal for mounting on carrier rails in switching cabinets. A
graphic display as well as a turn/push button for quick on-site control
of the measuring point are also integrated.
Itenablessimplepumpcontrol,owmeasurementonopenchan-
nels and weirs and totalization. With the VEGAMET 141, limit values
canbereliablymonitoredandrelayscanbeswitched,e.g.foroverll
protection according to WHG.
Due to its various possibilities it is suitable for many industrial
branches as well as plant manufacturers.
The VEGAMET 141 controller can power the connected sensor and
process its measurement signals. The requested parameter is shown
on the display and also output to the integrated current output for fur-
ther processing. The measurement signal can thus be transferred to a
remote display or a superordinate control system. Operating relays for
control of pumps or other devices are also integrated.
3.3 Adjustment
On-site operation of the device is carried out via the integrated display
and adjustment unit. It consists of a graphic display and a central turn/
push button for menu adjustment.
The optionally integrated Bluetooth module enables in addition a wire-
less adjustment of VEGAMET 141 via standard adjustment tool:
•
Smartphone/tablet (iOS or Android operating system)
•
PC/notebook with Bluetooth LE or Bluetooth USB adapter (Win-
dows operating system)
Information:
Certain setting options are not possible or only possible to a limited
extent with the integrated display and adjustment unit, for example the
settingsforowmeasurementorpumpcontrol.Fortheseapplica-
tions, the use of PACTware/DTM or the VEGA Tools app is recom-
mended. An overview of the available applications and functions as
well as their adjustment options can be found in the appendix.
Application area
Functional principle
Local adjustment