SI23 Solar Pump VFD Manual
24
Chapter 5 Parameters List
This chapter just provides function parameter table. Specifications refer to SI23 technical manual.
● Environment setting
Range of settings and definition
Factory default
(setting range)
V/F SVC FVC
Set the VFD initialization method
0: Not initialized
11: Select the set value according to the purpose to
carry out the parameters (excluding the motor
parameters)
22: All parameters are initialized
33: Clear the fault record
V/F SVC FVC
0: No function
11: Upload parameters to the keyboard
22: Download parameters to the VFD
V/F SVC FVC
Used to set the user password.
Range of settings and definition
Factory default
(setting range)
V/F SVC FVC
The way the motor is controlled.
0: AM-VF; VF control
1: AM-SVC; Open loop vector control, current
closed loop control
10: PM-VF; VF control
11: PM-SVC; Open-loop vector control
12: PM-FVC; Closed-loop vector control
16: SRM-SVC; Open-loop vector control
V/F SVC FVC
Used to select the channel that the drive accepts
the run and stop commands and the direction of
travel.
0: Keyboard control (external keyboard priority)
1: Terminal control
2: RS485 communication control
3: Reserved