SI23 Solar Pump VFD Manual
28
● Vector Control
Range of settings and definition
Factory default
(setting range)
ASR (speed
loop)proportional
gain 1
SVC
Set the ASR (speed loop) proportional gain 1.
ASR (speed
loop) integration
time 1
SVC
Set the ASR (speed loop) integration time 1.
ASR (speed
loop)proportional
gain 2
SVC
Set the ASR (speed loop) proportional gain 2.
ASR (speed
loop) integration
time 2
SVC
Set the ASR (speed loop) integration time 2.
Current loop
D-axis
proportional gain
SVC
Set the current loop D-axis proportional gain.
Current loop
D-axis integral
gain
SVC
Set the current loop D-axis integral gain.
Current loop
Q-axis
proportional gain
SVC
Set the current loop Q-axis proportional gain.
Current loop
Q-axis integral
gain
SVC
Set the current loop Q-axis integral gain.
Parameter
(address)
adjustable
attribute
Range of settings and definition
Factory default
(setting range)
Linear VF curve
selection
V/F
Used to select the type of V/F curve to meet
different load features.
0: Straight line VF curve
1-9: Respectively, a power VF curve of 1.1-1.9
10: Square VF curve
11: Custom VF curve
V/F
0.0%: automatic torque boost
0.1%~30.0%: manual torque boost