EasyManua.ls Logo

Veichi SI23 - Page 29

Veichi SI23
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SI23 Solar Pump VFD Manual
28
● Vector Control
Parameter
(address)
Function
Description
Range of settings and definition
Factory default
(setting range)
Notes
F03.02(0x0302)
ASR (speed
loop)proportional
gain 1
SVC
Set the ASR (speed loop) proportional gain 1.
10.00
(0.01100.00)
F03.03(0x0303)
ASR (speed
loop) integration
time 1
SVC
Set the ASR (speed loop) integration time 1.
0.100s
(0.000s6.000s)
F03.06(0x0306)
ASR (speed
loop)proportional
gain 2
SVC
Set the ASR (speed loop) proportional gain 2.
10
(0.01100.00)
F03.07(0x0307)
ASR (speed
loop) integration
time 2
SVC
Set the ASR (speed loop) integration time 2.
0.100s
(0.000s6.000s)
F03.10(0x030A)
Current loop
D-axis
proportional gain
SVC
Set the current loop D-axis proportional gain.
1.000
(0.0014.000)
F03.11(0x030B)
Current loop
D-axis integral
gain
SVC
Set the current loop D-axis integral gain.
1.000
(0.0014.000)
F03.12(0x030C)
Current loop
Q-axis
proportional gain
SVC
Set the current loop Q-axis proportional gain.
1.000
(0.0014.000)
F03.13(0x030D)
Current loop
Q-axis integral
gain
SVC
Set the current loop Q-axis integral gain.
1.000
(0.0014.000)
V/F Control
Parameter
(address)
adjustable
attribute
Function
Description
Range of settings and definition
Factory default
(setting range)
Notes
F04.00(0x0400)
Linear VF curve
selection
V/F
Used to select the type of V/F curve to meet
different load features.
0: Straight line VF curve
1-9: Respectively, a power VF curve of 1.1-1.9
10: Square VF curve
11: Custom VF curve
0
(011)
F04.01(0x0401)
Torque boost
V/F
0.0%: automatic torque boost
0.1%30.0%: manual torque boost
0.0%
(0.0%30.0%)

Related product manuals