SI23 Solar Pump VFD Manual
39
F21.11(0x550B)
Go to sleep mode
voltage
0V1000V
0V
F21.12(0x550C)
Wake up restore
voltage
0V1000V
400V
F21.13(0x550D)
Sleeping stop restore
waiting time
0.0s3000.0s
10.0s
F21.14(0x550E)
Low speed protection
detect frequency
0.00Hz300.00Hz
10.00Hz
F21.15(0x550F)
Low speed
protection detect time
0.0s3000.0s
10.0s
F21.16(0x5510)
Low speed protection
restore working time
0.0s3000.0s
10.0s
F21.17(0x5511)
Dry run protection
detect current
0.0A999.9A
0.0A
F21.18(0x5512)
Dry run protection
detect time
0.0s3000.0s
10.0s
F21.19(0x5513)
Dry run auto restore
working time
0.0s3000.0s
10.0s
F21.20(0x5514)
Over current point
setting
0.0A999.9A
0.0A
F21.21(0x5515)
Over current
protection detect time
0.0s3000.0s
10.0s
F21.22(0x5516)
Over current
protection auto
restore working time
0.0s3000.0s
10.0s
F21.23(0x5517)
Input minimum power
protection power point
setting
0.00kW650.00kW
0.00kW
F21.24(0x5518)
Minimum power
protection detect time
0.0s3000.0s
10.0s
F21.25(0x5519)
Minimum power
protection auto
restore working time
0.0s3000.0s
10.0s
F21.26(0x551A)
Fault alarm restore
mode
0:Auto reset;1:Reset by manual
LED0:Low speed protection
LED1:Dry run
LED2:Over current protection
LED3: Minimum power protection
0000