SI23 Solar Pump VFD Manual
40
F21.27(0x551B)
Water fulfilled detect
time
0.0s3000.0s
10.0s
F21.28(0x551C)
Water fulfilled restore
time
0.0s3000.0s
10.0s
F21.29(0x551D)
reserve
F21.30(0x551E)
DC current revise
offset
0.00A99.99A
0.01A
F21.31(0x551F)
DC current revise
proportion gain
0.0%999.9%
100.0%
F21.32(0x5520)
Power curve point 0
0.00kW99.99kW
0.50kW
F21.33(0x5521)
Power curve point 1
0.00kW99.99kW
1.00kW
F21.34(0x5522)
Power curve point 2
0.00kW99.99kW
1.50kW
F21.35(0x5523)
Power curve point 3
0.00kW99.99kW
2.00kW
F21.36(0x5524)
Power curve point 4
0.00kW99.99kW
2.50kW
F21.37(0x5525)
Flow curve point 0
0.0m³/h999.9m³/h
0.0m³/h
F21.38(0x5526)
Flow curve point 1
0.0m³/h999.9m³/h
5.0m³/h
F21.39(0x5527)
Flow curve point 2
0.0m³/h999.9m³/h
10.0m³/h
F21.40(0x5528)
Flow curve point 3
0.0m³/h999.9m³/h
15.0m³/h
F21.41(0x5529)
Flow curve point 4
0.0m³/h999.9m³/h
20.0m³/h
F21.42(0x552A)
Flow calculating
revise offset
0.0m³999.9m³
0.0m³
F21.43(0x552B)
Flow calculating
revise gain
0.0%999.9%
100.0%
F21.44(0x552C)
Power per day/
generated power per
day reset period
0.0h24.0h
7.0h
F21.45(0x552D)
Reserved
F21.46(0x552E)
Photovoltaic pump
function selection 1
0:Invalid
1:Valid
LED0:Constant torque frequency limit
selection
LED1:Reserved
LED2:Voltage rising update Voc voltage
LED3: Fast frequency falling function
1100H
F21.47(0x552F)
Fast frequency falling
threshold
3.0%15.0%
5.0%
F21.48(0x5530)
Constant torque
frequency limit
coefficient
80.0%150.0%
100.0%