Press the “clean” button for two seconds in order to save the
values. Two audible beep signals indicate that the values have
been saved successfully.
6.3 Setting instructions for the pressure levels (cleaning version)
The pressure level can be changed at any time during operation.
Pressing the corresponding button (P1, P2 or P3) changes the
pressure level temporarily. Pressing the button longer (2 seconds,
approx.) changes the pressure level permanently. This means that
the selected pressure level is also used when switching the device
on the next time.
Button Pressure level Steam temperature
P1 3 bar / 0.3 MPa,
approx.
130°C, approx.
P2 4 bar / 0.4 MPa,
approx.
140°C, approx.
P3 5 bar / 0.5 MPa,
approx.
150°C, approx.
Saving the values
Commissioning
Setting instructions for the pressure levels (cleaning version)
30.09.2022
Steam generator VEIT SG67
33