This will complete the cleaning program.
11. The steam generator has now been cleaned. The device fills
the boiler with water and heats up to the relevant pressure
level. The device is ready to operate again.
NOTICE!
In general, the following applies:
2 x flashes/beeps: Blow-down
3 x flashes/beeps: fill in cleaning agent
NOTICE!
If the cleaning program has not been performed
properly (e.g. caused by switching off the steam
generator, or due to a power failure during the
cleaning process), the steam generator must be
switched on again as soon as possible because
SteamClean remaining in the system may damage
certain components/parts. Depending on the time
of interruption, the steam generator can respond in
two different ways:
Interruption before “SteamClean filled into
cleaning tank” confirmation:
The steam generator indicates again that
the cleaning program must be run.
The operator must check whether or not
SteamClean has already been filled into
the cleaning tank.
Restart the program and, if required, fill
in SteamClean. Otherwise, simply confirm
with “Steam clean filled into cleaning tank”.
Interruption after “SteamClean filled into
cleaning tank” confirmation:
The steam generator fills SteamClean/
water into the boiler until the required water
level has been reached.
The cleaning program will be continued.
If there is an unpleasant, pungent odour during
steaming immediately after running the cleaning
program, residues of the cleaning agent might still
be in the steam generator.
Make sure to supply fresh air
Switch off the steam generator
Blow down the steam generator
Ä
Chapter 8.2
‘Blow-down’ on page 42
Restart the steam generator.
Maintenance and cleaning
Cleaning program (cleaning version)
30.09.2022
Steam generator VEIT SG67