3/2002
PC-15
SET-UP AND CODE DESCRIPTION (CONTINUED)
Light Setting During Low Energy
This feature is an additional sub-mode of nrG1/nrG2. This will let you choose if the lights are
included or excluded from the low energy operation. If selection button two is pressed at the
“LItX” prompt, the controller will enter the Light Setting Option. Upon entry into this program
the display will show the current setting “LIty” for enabled and “LItn” for disabled. If selection
button one is pressed and released it will toggle through the valid selections. Pressing
selection button three will save the currently displayed setting and return the user to the
“CtL1” prompt.
Itx
“Y” = Enable low energy option.
“N” = Disable low energy option.
Refrigeration Temperature Set Back During Low Energy
This feature is an additional sub-mode of nrG1/nrG2. This will let you choose if the
refrigeration system is included or excluded from the low energy operation. If selection
button two is pressed at the “rFGy” prompt, the controller will enter the Refrigeration Setting
Option. Upon entry into this program the display will show the current setting “rFGy” for
enabled and “rFNn” for disabled. If selection button one is pressed and released it will toggle
through the valid selections. Pressing selection button three will save the currently displayed
setting and return the user to the “CtL1” prompt.
FGx
“Y” = Enable temperature set back.
“N” = Disable temperature set back.