12
UVS27 Vent-Free Gas Heater
20007068
Check the Rating Plate attached by a steel cable to the
firebox, to confirm that you have the appropriate firebox
for the type of fuel to be used.
The appliance should have a main gas valve provided
in an accessible location for turning on or shutting off
the gas to the main burner.
Gas connection should be made in accordance with
current National Fuel Gas Code, ANSI Z223.1/NFPA
54. Since some municipalities have additional local
codes, be sure to consult you local authority.
Connect the gas supply and test for leaks. Use a 50/50
solution of liquid soap and water to test for leaks at gas
fittings and joints. NEVER test with an open flame.
Light the pilot according to the directions on Psage 17,
before going to the next step.
1. Remove the logs from their packaging, and inspect
each piece for damage.
2. Install the rear log by placing it on the sheet metal
shelf at the back of the firebox. (Fig. 17) The log
should touch the back wall of the firebox and be
centered.