380602.01 7
vetus® Installation manual Generator Sets GHX / GLX
Add coolant or water to the coolant circuit if necessary.
Close the cap.
Start the engine and verify if the engine is running normal.
2.3 Long engine storage – Inactivity
If the engine remains inactive for a period of time exceeding 6 months, you need to protect it from oxidation and break-
downs in accordance with the following instructions:
Drain o the water from the fuel system and ll the fuel tank.
Make sure that the engine fuel system is lled with a fuel mixture with protective properties.
Flush out the raw water circuit with fresh water and if necessary ll with antifreeze. Clean the heat exchanger if nec-
essary.
Make sure that the cooling system is lled with a suitable anti-freeze.
Let the engine run for 15 minutes without load; stop the engine and change the oil lter and the engine oil.
Put oil (according to the specications into the oil sump until the oil sump reaches at least ‘Min on the oil dipstick.
Oil 15 W40, API: CF4, CG4, CH4, CI4 or ACEA: A3/B3, A3/B4, E7
For example: Vetus Marine Diesel Engine Oil 15 W40
Shell Rimula R4 15W40
Disconnect the battery cables, charge the batteries if necessary and grease the battery terminals.
After a period of inactivity, it is necessary to carry out a some maintenance work before starting the engine again
to ensure its eciency conditions.
Check the battery charge level conditions. Assure that the battery voltage is over 12.5 V.
Make sure the electric contacts are intact. Assure the correct electrical connections.
Carry out the engine diagnosis.
Check the oil level-conditions, and if necessary, top- up or replace.
Verify and if necessary replace the oil lter.
Check the coolant level an mixture, and if necessary top – up.
Replace / Clean the fuel lter.
Clean the air lter.
Verify the belts status and tighteners.
Verify the integrity of the sea water pump impeller.
Check the integrity of zinc anodes, is present.
Verify and if is necessary grease: starter pinion.
Start the engine and run without load for few minutes.
If no anomalies bring the engine to its operating temperature, 70 - 80 °C (158 - 176 °F). Verify that there is no air in the
coolant circuit – bleed the air from coolant circuit if necessary.
Turn o the engine and check again the engine oil level and coolant level.
Verify for tightening.