TROUBLE SHOOTINGS
Some malfunctions of the grinder are not practically serious. You can
correct it by yourself. To diagnose and find a solution to the Trouble, refer
to the diagram below. For other malfunctions, contact the supplier or a
qualified professional.
MALFUNCTIONS
POSSIBLE CAUSES
SOLUTIONS
The appliance occasionally
starts to work
The connected pipelines are
leaking
Check the installation in front
of the appliance
The check valve is leaking
Clean or replace the check valve
The motor is running properly,
but the water runs slowly
away.
The aerator in the lid is blocked
Clean the aerator
The engine is running
properly but non-stop or runs
for a long time
The height or length of the drain
is too large,or too many bends
are used(power failure)
Check the installation
The pump is blocked
Turn off the power,
disassemble the pump and
unblock
The motor is not switched on
The power supply is not
switched on
Switch the on power supply
(repeat)
The plug is defective
Repair the plug
The trouble with the motor or
sensor
Remove the lid,flush clean,and
dry the sensor up(hair dryer)
The motor rattles with a noise
There's a strange object in the
motor
Remove the lid,clean it and
remove the object
The motor is buzzing and
does not rotate
The condensator is broken or has
trouble with the motor
Get in contact with a qualified
specialist or the supplier
There's a strange object in the
Remove the lid,clean it and
motor
Remove the lid,clean it and
remove the object