- 7 -
14. If it is difficult to start the unit, please turn the Switch two rounds
to balance the internal pressure and make it easier to start the unit*
15. The Low Pressure Gauge shows the pressure of the intake port
of the compressor and the High Pressure Gauge shows the
pressure of the outlet port of the recovery unit.
16. After using, please turn the knob to "0" position.
SPECIFICATION
MODEL
RR250
RR500
Refrigerants
Category : R12, R134a, R401C, R406A, R500
Power
110-120VAC 60Hz, 220-240 VAC 5O-6OHz
Motor
3/4HP, Single cylinder
system
1 HP,twin cjdinder system
Motor Speed
1450rpm^)50Hz
1750rpm{a)60Hz
Maximal
Current Draw
110V:8A 220V:5A
110V:10A 220V:SA
Compressor
Oil-less, Air-cooled, Piston
High Pressure
Shut-off
383 bar/38S0kPa(558psi)
Catego
ry
Categor
y IV
Categor
y V
Categor
y
Categor
y IV
Categor
y V
Vapor
0. 20
0. 25
0.25
0.40
0.50
0.50
Recovery
Rate(kg/ min)
Liquid
1. 60
1. 80
2.20
3.00
3.50
3.50