TM68
EN
DISPLAY AND KEY
INDICATIONS
CAUSE EFFECT SOLUTION NOTES
PRESSURE ERROR
When the machine’s temperatu-
re is higher than 130°C.
Thedisplayindicatorwillashon
and off and the resistor is
de-activated.
The system will be re-established
as soon as the temperature goes
below 130°C.
The boiler is provided with a ma-
nualrettingsafetythermostat;if
the resistor is not re-established,
callaqualiedtechnician.
OVERCURRENT ERR.
Incorrect electrical input caused
by a malfunction in one of the
machine charges.
Thedisplayreadingwillash.The
pump will switch off. The heating
element and all other functions
will be disabled.
Switch off the machine and send
for a specialist technical
engineer.
FINE GRINDING
The machine registers values
different from the set values.
A much longer delivery time.
Modify grinding degree and
press the key RESET or one of
the keys
 .
By leaving the machine in the
programming state, within 10
minutes from the last selection,
the system will return to the pre-
vious congurationand the dis-
play will indicate its reestablish-
ment of normal functioning.
COARSE GRINDING
The machine registers values
different from the set values.
A much shorter delivery time.
Press the RESET key or one of
the keys
 .

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Victoria Arduino ADONIS 3 gruoups and is the answer not in the manual?

Victoria Arduino ADONIS 3 gruoups Specifications

General IconGeneral
BrandVictoria Arduino
ModelADONIS 3 gruoups
CategoryCoffee Maker
LanguageEnglish

Related product manuals