Input Voltage | 230 VAC |
---|---|
Input Voltage Range | 180-265 VAC |
IP Rating | IP65 |
Output Voltage | 12V / 24V (depending on model) |
Protection | Over temperature |
Communication | Bluetooth |
Operating Temperature | -20 to +50 °C |
Output Current | 5A / 10A / 15A |
Charging Algorithm | Multi-stage adaptive |
Setup, configuration, monitoring, and firmware updates via VictronConnect app.
Presets for common battery types with adaptive charge logic; advanced configuration.
Optimizes recharge cycles and charge maintenance over extended periods.
Monitors battery response to determine optimal absorption duration for full recharge.
Automatically compensates charge voltage based on ambient temperature.
Engineered for years of trouble-free operation with protections against overheating and short circuits.
Totally silent operation via natural convection; full rated output up to 30°C.
Compatible with Li-ion (LiFePO4) batteries; handles UVP trips.
Extends battery life by maintaining full charge when unused.
Optional stage to recover lead-acid battery degradation due to sulfation.
Limits maximum charge current for lower capacity batteries.
Attempts to recharge severely discharged batteries (down to 0V).
Allows the charger to be used as a DC power supply.
Multi-stage algorithm to optimize recharge and maintenance over extended periods.
Maintains battery voltage at a reduced level to minimize gassing and extend battery life.
Refreshes battery to prevent self-discharge in storage stage; occurs automatically.
Automatically compensates charge voltage based on ambient temperature for lead-acid batteries.
Describes conditions that trigger a new charge cycle, including AC power reconnection.
Calculates bulk stage duration and total charge time based on battery capacity and current.
Details the 3 integrated charge modes (Normal, High, Li-ion) and Recondition stage.
Table showing voltage settings for each charge stage across different modes.
Enables the recondition stage for corrective/maintenance actions.
Limits maximum charge current for lower capacity batteries to prevent damage.
Guide to using the VictronConnect app for setup, configuration, and monitoring via Bluetooth.
Manages Bluetooth connectivity, including PIN code, disabling, and re-enabling.
Instructions for changing the default Bluetooth PIN code for enhanced security.
Procedure to reset a forgotten or lost Bluetooth PIN code to the default 000000.
Options to disable Bluetooth permanently or for 30 seconds after power-up.
Procedure to re-enable Bluetooth after disabling it for 30 seconds.
Restores all charger/battery settings to default values using VictronConnect.
Main overview screen displaying battery voltage, charge current, and active charge stage.
Graphical representation of charge stages with battery voltage and charge current.
Provides historical usage data and statistics for the last 40 charge cycles.
Enables specific configuration of charge parameters and user-defined settings.
Expands advanced settings to include more specialized configuration options.
Allows the charger to be used as a DC power supply, disabling internal charge logic.
Provides detailed physical dimensions and model numbers for the charger.