9.3. Appendix C: parallel connection
9.4. Appendix D: three-phase connection
9.5. Appendix E: charge algorithm
4-stage charging:
Bulk: Entered when charger is started. Constant current is applied until the gassing voltage is reached (14.4V resp. 28.8V,
temperature compensated).
MultiPlus 2kVA 230V
Page 22 APPENDIX