What to do if the alarm LED flashes on my Victron Energy Inverter?
- KKimberly AcostaAug 16, 2025
If the alarm LED is flashing on your Victron Energy Inverter, it could be due to several reasons: * The DC input voltage is low: Charge the battery or check the battery connections. * The ambient temperature is too high: Place the inverter in a cool and well-ventilated room or reduce the load. * The load on the inverter is higher than the nominal load: Reduce the load. * Voltage ripple on the DC input exceeds 1.25Vrms: Check the battery cables and terminals. Check the battery capacity and increase it if necessary. * Low battery voltage and excessive load: Charge the batteries, reduce the load or install batteries with a higher capacity. Use shorter and/or thicker battery cables.