CONTROL CABINETS - TECHNICAL MANUAL EN-UK - V.1.3 - 14/07/16
14
DE
AUDIO & VIDEO CONTROL CABINETS
Mode Up Down Select
On/Off
VIDEX
110mm 30mm
70mm
Art.701T Dimensions
Terminal Connections
Input Voltage : 12Vac or 12Vdc, +6% -10%
Current (standby, relay OFF) : 47mA
Current (standby, relay ON) : 67mA
Battery Back-up : Min. 3 days
Relay Contacts (dry contacts) : 3A at 24Vdc, 3A at 120Vac
Time Bands Available : 6 (ON/OFF period 1 will switch OFF at the OFF time for that period
regardless of manual override. ON/OFF periods 2-6 won’t switch OFF at
the OFF time for that period if override is pressed)
Time Accuracy : less than + or - 2 seconds drift per day
Trade Mode Relay Time : From 1 second up to 99 seconds
Module Dimensions : 110mm (L) x 70mm (W) x 30mm (D)
Jumpers (JP1 and JP2) : JP1 (A = Trade mode, B = Time clock mode)
JP2 (A = BST/GMT correction disabled, B = BST/GMT correction enabled)
Working Temp. : -10
o
C +50
o
C
Technical Specications
Terminal Function
+ 12Vac or dc input
- 0V (ground)
- 0V (switched 0V ground output for TR connection) Normally open going closed
trade button connections
TR Switched 0V trade button trigger (from 0V ground output)
CO Common connection on relay
NO Normally open connection on relay
NC Normally closed connection on relay