CONNECTION TO MAINS
The system must be installed according to national rules in force, in particular we recommend to:
• Connect the system to the mains through an all-pole circuit breaker which shall have contact separation of at least 3mm in each
pole and shall disconnect all poles simultaneously;
• The all-pole circuit breaker shall be placed for easy access and the switch shall remain readily operable.
POWER SUPPLY INSTALLATION
• Remove the terminal side covers by unscrewing the retaining screws;
• Fix the power supply to a DIN bar or directly to the wall using two expansion type screws;
• Switch o the mains using the circuit breaker mentioned above and then make the connections as shown on the installation diagrams;
• Check the connections and secure the wires into the terminals;
• Replace the terminal covers and x them using the relevant screws;
• After completing the wiring, double check all connections then restore the mains.
CABLE SIZE
Video connections and Audio connections must be wired in twisted pair: pair the video lines (terminals/signals V1 and V2), pair
the audio lines (terminals /signals 1 and 2).
IMPORTANT NOTE: SOLID COPPER CABLES MUST BE USED. COPPER COATED STEEL CCS AND COPPER COATED
ALUMINIUM CCA CAN NOT BE USED ON THE SYSTEM.
+V *
*
1
V1
V2
2
Power
supply
Videophone
Up to 40mt
2 wires
Ø 1mm
20mt max
Outdoor
station
BROWN
ORANGE
BLUE
GREEN
WHITE/BROWN
WHITE/ORANGE
WHITE/BLUE
WHITE/GREEN
Distance
Suggested cables type
Up to
40mt
CAT5/CAT6
FTP/UTP/CW1308
AWG24/0.22mm
2
* Double up the two wires to increase
the cross section and reduce the re-
sistance.
1
V1
V2
+V
2
1
V1
V2
+V
2
1
V1
V2
+V
2
Power
supply
Videophone
Up to 50mt
Outdoor
station
Outdoor
station
Outdoor
station
"+V" and "–"
Ø 0.35mm
"V1" and "V2"
Ø 0.35mm Twisted pair
"1" and "2"
Ø 0.35mm Twisted pair
20mt max
2 wires
Ø 1mm
from 50 to 100mt
"+V" and "–"
Ø 0.75mm
"1" and "2"
Ø 0.5mm Twisted pair
"V1" and "V2"
Ø 0.5mm Twisted pair
from 100 to 200mt
"+V" and "–"
Ø 1.5mm
"V1" and "V2"
Ø 0.75mm Twisted pair
"1" and "2"
Ø 0.75mm Twisted pair
Distance Suggested cables type
Up to
50mt
4 pair (8 cores) 0.35mm
AWG22 - 48/Km
From
50 to
100mt
3 pair (6 cores) 0.8mm
AWG18 - 19.2/Km
From
100 to
200mt
4 pair (8 cores) 0.8mm