37
Tecto FI2 84 PI
EN 428001335137
Use and maintenance manual
Turn off the appliance, wait a few hours until all the condensing unit appliances have reached a temperature that is close to
room temperature.
Remove the protection grids (front and rear) as indicated.
17.2 CONDENSING UNIT
Clean the condenser using a dedicated soft bristle brush and a vacuum cleaner; perform
the operation being careful not to bend the plates of the condenser itself.
17.3 DEFROST WATER COLLECTION TRAY (IF PRESENT)
Clean based on use and as needed and in certain environmental conditions (e.g., high humidity, low environmental temperature,
presence of dust, etc.) in order to avoid the incorrect and complete evaporation of the water and/or the presence of unpleasant
odours.
Disinfect the tray with suitable products.