24
Cylinder capacity l 160 200 300
Type CVAA CVAB-A CVAA CVAB-A CVAA
DIN registration number 9W241/11–13 MC/E
Standby heat loss
To EN 12897:2016
Q
st
with 45 K temperature differential
kWh/24 h 1.16 0.93 1.39 1.00 1.65
Dimensions
Length (7)
■
Incl. thermal insulation mm 581 581 667
■
Excl. thermal insulation mm — — —
Width
■
Incl. thermal insulation mm 605 605 744
■
Excl. thermal insulation mm — — —
Height
■
Incl. thermal insulation mm 1189 1409 1734
■
Excl. thermal insulation mm — — —
Height when tilted
■
Incl. thermal insulation mm 1260 1460 1825
■
Excl. thermal insulation mm — — —
Entire weight incl. thermal insulation kg 86 97 156
Connections (male thread)
Heating water flow and return R 1 1 1
Cold water, DHW R ¾ ¾ 1
DHW circulation R ¾ ¾ 1
Immersion heater EHE
IP rating: IP 44
Output range Max. 6 kW Max. 12 kW
Rated consumption in standard
mode/during quick heat-up
kW 2 4 6 4 8 12
Current type and rated voltage
Rated current A 8.7 17.4 8.7 10.0 20.0 17.3
Heat-up time from
10 to 60 °C
300 l h 7.4 3.7 2.5 — — —
500 l h 11.9 5.9 4.0 — — —
DHW cylinder with immersion heater EHE
Cylinder capacity l 300
Dimensions
Width (incl. immersion heater EHE)
mm 843
Minimum wall clearance for the installation
of an immersion heater EHE
2/4/6 kW mm 685
4/8/12 kW mm —
Weight Vitocell 100-V kg 156
Immersion heater
EHE
2/4/6 kW kg 2
4/8/12 kW kg —
Heating lance (accessories)
DHW cylinder: Vitocell 100-V/-W, type CVAA, 300 l
Content that can be heated with the heating lance: 248 l
Specification
Specification
6150608
Appendix