To ensure continued efficient operation of the appliance, it is recommended that
it is checked and serviced as necessary at regular intervals. The frequency of
servicing will depend upon the particular installation conditions and usage but in
general once a year should be adequate. It is the law that any service work
must be carried out by a competent CORGI registered person.
The boiler incorporates a flue sampling point in front of the flue outlet. The flue
gases can be analysed if required. The push fit cap may be removed and a sam-
ple tube fitted. The push fit cap must be replaced after use. The flue gas sample
will enable the service engineer to judge whether any major action is required.
Before commencing any service operation, isolate the mains electrical supply
and turn off the gas supply at the main service cock.
Removing front panel
1. Remove the screw at the top of the
boiler.
2. Press down the springs on the
underside of the boiler.
Routine Servicing Instructions
52
Service Instructions
5581 805

Other manuals for Viessmann Vitodens 100-W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Viessmann Vitodens 100-W and is the answer not in the manual?

Viessmann Vitodens 100-W Specifications

General IconGeneral
TypeWall-mounted gas condensing boiler
InstallationWall-mounted
Fuel TypeNatural gas or LPG
Heat Exchanger MaterialStainless steel
EfficiencyUp to 98%
WarrantyUp to 10 years (depending on installation and usage)
ControlVitotronic control unit with LCD display
Dimensions700mm x 400mm x 350mm
Heating Output1.9 to 35 kW

Related product manuals