Viessmann Vitodens 300 - Page 79

Viessmann Vitodens 300
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Displayed
fault c ode
Con-
st.
Weat -
her-
com-
p.
System
character-
istics
Cause Remedy
51 X X No DHW
heating
Cylinder tem-
perature sen-
sor 2/outlet
sensor lead
break
Check sensor s (se e
page 87)
59 X X No DHW
heating
Cylinder tem-
perature sen-
sor 2/outlet
sensor lead
break
Check sensor s (se e
page 87)
92 X X Control
mode
Solar: Colle c-
tor tempera-
ture sensor
shorted out
Check sensor
9A X X Control
mode
Collector tem-
perature sen-
sor lead break
Check sensor
93 X X Control
mode
Solar: Sensor
S3 shorted out
Check sensor
9b X X Control
mode
Sensor S 3
lead break
Check sensor
94 X X Control
mode
Solar: Cylinder
temperature
sensor
shorted out
Check sensor
9C X X Control
mode
Cylinder tem-
perature sen-
sor lead break
Check sensor
9F X X Control
mode
Solar control
unit fault me s-
sage
See solar control
unit service instruc-
tions
A7 X Control
mode
Faulty user
interface
Replace user inte r-
face
b0 X X Burner
blocked
Flue gas tem-
perature sen-
sor short
circuit
Check the flue gas
temperature sensor
(see page 89)
Checking and acknowledging faults (cont.)
79
Troubleshooting
5692 537 GB