Switch position I for central heating
return from the left (delivered condi-
tion).
&
Switch position II for central heating
return from the right.
Checking the Vitotronic 050 (accessories)
The Vitotronic 050 is connected to the control unit via the LON system. To test
the connection, implement a user check at the boiler control unit (see page 31).