5.2 ADC Calibration
(1)Open the image of Gray16.
(2) Enter the engineering Mode, and then move down the color bar to “ADC Calibration” item.
(3) Press right button to execute ADC Calibration. C olor deviation is unacceptable.
If the screen blinks once, and then back to search signal and at last search out the image of
Gray16, this indicates the calibration is successful.
Confidential - Do Not Copy
ViewSonic Corporation
Pro8400
39