Troubleshooting
10 ©2012 Viking Preferred Service
Component Characteristics
Component Testing
Component
Operating Voltage
(Approximate)
*Resistance
(Approximate)
Test Location
Oven Control Board 120 VAC 93.6 W On Control Board -
P20 (L1 black) to P19 (N white)
Direct Spark Module -
Bake selected
120 VAC Not Applicable On DSI Module -
H1 violet to N white
Direct Spark Module -
Broil selected
120 VAC Not Applicable On DSI Module -
H2 blue to N white
Bake Solenoid Valve 10.5 VAC 210 W On DSI Module -
S1 brown to SC white/black
Broil Solenoid Valve 10.5 VAC 210 W On DSI Module -
S2 yellow to SC white/black
RTD (Resistive
Thermal Device)
- 1090 W at 75°F
(See chart for more
options)
On Control Board -
P15 grey to grey on connector
Convection Motor 120 VAC 39.4 W Convection Relay on Control Board -
P5 (white/red) to P19 (N white)
Lock Motor 120 VAC 6.82 KW Lock Motor Relay on Control Board -
P6 (white/black) to P19 (N white)
Cooling Fan 120 VAC 18.1 W Cooling Fan Relay on Control Board -
P11 (yellow) to P19 (N white)
**High Limit - open
contacts
120 VAC Open Quick power disconnect black to P20 (L1 black)
disconnect from Control Board
**High Limit - closed
contacts
0 VAC 0 W Power cord black to P20 (L1 black) on Control
Board
Cycle Light 120 VAC Open 127.5 KW
(neon light)
On cycle light terminals - grey to white
Clean Light 120 VAC Open 127.5 KW
(neon light)
On clean light terminals - white to violet
Oven Door Light
Switch - OFF (Door
Closed)
120 VAC Open On oven light switch terminals - black to red
Oven Door Light
Switch - ON (Door
Closed)
0 VAC 0 W On oven light switch terminals - black to red
Oven Light Switch -
Light Switch Open
120 VAC Open On oven light switch terminals - black to red
Oven Light Switch -
Light Switch Closed
0 VAC 0 W On oven light switch terminals - black to red
Single Point Spark
Module
120 VAC Not Applicable On Single Point Spark Module - black to white
*Resistance checks made with power off.
**High limit switch is N.C. (normally closed) and opens at 275°F, resets at 250°F (+/- 10°F).