Fault diagnosis
Fault Possible cause Fault rectification
Water discharge has
been detected
Hoses are leaking
Make sure that the connection
spigot has been pushed into the
water connection adequately and
is properly sealed.
Make sure that the seals and the
sieve seal on the inlet and outlet
of the solenoid valve have been
mounted in the correct position.
Make sure that the two union
nuts on the inlet and outlet of
the solenoid valve are tightened
adequately and properly.
Make sure that the hose
connections are screwed into the
connection spigot adequately.
Make sure that the seal ring on
the connection spigot is fitted
correctly.