Installation
2
2.1 Installing Filter on Water Line
Note: Filter can be adapted to various pipes by using reducing adapters on either end. Installation fittings can be sweated
or threaded. Use galvanized fittings for installation on galvanized pipe.
Procedure:
NOTICE
Before starting, shut off the main water supply and drain pipes.
• Loose fit all parts and
calculate length of pipe to be
removed.
• Cut the pipe and install
fittings.
• Screw filter to the adapter
after covering the threads
with Teflon
™
tape and make a
tight connection but do not
over tighten.
Note: If space is limited
remove sump from head
while making connection.
• Connect and tighten, making
sure filter is in a straight
vertical position.
Jumper Wire
Note: If water pipes are used to
ground electrical system,
appliances, or phone, install a
jumper wire.
By-pass section:
• Can be installed around unit if
desired using either threaded
or sweated fittings.