EN - 19
APPENDIX
Stop Local Off
Setting a stop in Local Off mode means that it will not be played by the organ’s internal sound generation
system, but the relative MIDI (System Exclusive code) message will be transmitted, so that it can be turned on
and played on a connected instrument.
To set a stop in Local Off mode, while the main screen is on the display, press
the [S] thumb piston, keep it pressed and also press the [C] or [CANC] thumb
button. The Leds of all the stops will light up and the display will show a pop-up.
To set a voice in Local Off mode, operate its draw-stop or rocker switch so that
its light goes out.
After setting the setup required, press [S] and [C] or [CANC] together to save it.
Accessing the Local Off setting function after this will trigger display of the status
of the stops as follows:
Light on: stop in Local On mode (plays with internal generation)
Light off: stop in Local Off mode
Upgrading the operating system
The operating system of the Physis Plus organs can be easily and quickly update. Each time an update file is
released it will be made available on the website http://www.viscountinstruments.com. After the .ZIP file has
been downloaded, extract the .PHX file and copy it to the main folder (root) of a USB flash drive, plug it in the
USB connector under the manuals, then recall the OP.SYS. UPGRADE function located in the UTILITY menu.
After this, the display will inform you the release number that will be installed and after [MENU/ENTER] button is
pressed, the upgrade phase starts.
- Do not disconnect the USB flash drive or switch off the instrument during the update procedure.
-
It is strongly recommended to use USB flash drives containing only one partition. If USB flash contains
two or more partitions (even if hidden), copy the update file to the first partition. By copying the update
file to other partitions, this is not detected by the instrument, displaying the error message "No version
found on USB pen".
- Please make sure that the root folder of the USB flash unit contains only one .PHX update file.